Rodent Glucose Clamp
For Rats
Maximize the accuracy and efficiency of your rat insulin and glucose studies with high-quality supplies from SAI.
Conducting insulin sensitivity studies can quickly become complex, but we’re here to simplify the process and support your research goals. Whether your study involves Glucose Tolerance Tests (GTT), Hyperglycemic Clamp techniques, or Hyperinsulinemic-Euglycemic Clamp protocols, we provide expert guidance and carefully selected recommendations to ensure accurate and reproducible results. Explore our resources and product suggestions below to streamline your workflow and achieve reliable outcomes in your insulin sensitivity research.
Supplies for ITT and GTT Studies
In this study design, a loading dose of glucose (gtt) or insulin (itt) is followed by intermittent blood sampling. The dose is typically administered orally, and since multiple blood samples are needed, an access port is the best tool to make catheter access quick and easy.
Rounded tipped rodent jugular vein catheter with beads at 2.6 and 3cm from the tip
You will find a wide variety of JVC options below, but all of these catheters are constructed of biocompatible materials for low vessel trauma and increased patency. Rounded Tip- Our most popular catheters are our rounded-tip catheters. Rounded tips reduce trauma during implant as well as during subsequent catheter manipulation leading to[...]
Disposable Feeding Needle, Rat, Sterile, 100mm, Grey with Bite Guard
These PTFE feeding needles are designed to reduce the risk of trauma and bite-through, providing a safe, low cost, disposable, solution for oral gavage. SAI's affordable feeding tubes boast distinct features, including a soft silicone tip, a smooth plastic PTFE shaft and an optional, bite-resistant, stainless steel bite-guard for maximum[...]
CannuLock™ Ports, 25G Red, 10 sterile pouches of 2 each, 20 ports total
SAI's Catheter Access Ports™ offer all new CannuLock™ technology, providing a remarkably secure connection between your catheter and the port. The carefully designed barbed connector locks with the catheter to eliminate the risk of slipping or disconnecting. CannuLock™ technology is also available in our Catheter Access Button™. Smooth barb safely "locks"[...]
Supplies for Hyperglycemic Clamp Studies
In this study design, IV glucose is infused and adjusted to reach a steady state, followed by intermittent blood sampling to establish glucose levels. Since the rat must be tethered, and low-stress, the CannuLock™ Catheter Access Button™ is an ideal tool.
Rounded tipped rodent jugular vein catheter with beads at 2.6 and 3cm from the tip
You will find a wide variety of JVC options below, but all of these catheters are constructed of biocompatible materials for low vessel trauma and increased patency. Rounded Tip- Our most popular catheters are our rounded-tip catheters. Rounded tips reduce trauma during implant as well as during subsequent catheter manipulation leading to[...]
Rat Femoral Polyurethane Artery Catheter
Rat arterial catheters are designed to enter the smaller, more muscular vessels while maintaining strength and durability at the externalization point. SAI offers both a tapered and a step-up option. Minimum order quantity is 5 pieces. For pricing on fewer than 5 catheters, please contact us. For placement in rat arteries, including carotid[...]
Bile collection 25G swivel to tube extension lines 3/pk
This extension line is a perfect fit for our CannuLock™ Bile Collection System. The polyurethane tubing is press fit to the 25G dual pin swivel and runs from the top of the swivel down to your collection vial. 3/pk, ETO sterilized Fits 25G Swivel Connection 33″ length, or request the[...]
CannuLock™ Ports, 25G Red, 10 sterile pouches of 2 each, 20 ports total
SAI's Catheter Access Ports™ offer all new CannuLock™ technology, providing a remarkably secure connection between your catheter and the port. The carefully designed barbed connector locks with the catheter to eliminate the risk of slipping or disconnecting. CannuLock™ technology is also available in our Catheter Access Button™. Smooth barb safely "locks"[...]
Shunting Cap, Multi-Channel CAB, P1 and P3
These lightweight metal caps connect and protect SAI Catheter Access Buttons™, allowing you to group house your animals without worry. Catheter Access Button™ Standard Caps Magnetic, so cap is self-aligning, attaching quickly and easily Cap is lightweight but durable, allowing worry free group housing Three colors available for easy identification of[...]
Triple Channel CAB w/ CannuLock™ , 22G
Our safe and secure rat Catheter Access Buttons™ feature CannuLock™ technology for the best catheter fit. The smooth barbed connector locks with a catheter to eliminate the risk of slipping or disconnecting. You may also like CannuLock™ ports, adapters and tethers. Smooth barb safely "locks" with a catheter to eliminate disconnections[...]
12” Quick Connect Tether, Single Channel CAB, 22G P2
SAI's Catheter Access Buttons™ offer all new CannuLock™ technology, providing a remarkably secure connection for up to three catheters. Our 1, 2, and 3 channel tethers make connections even easier with smart alignment features. The alignment arrows and unique “keyed” geometry of SAI's buttons allow you to access only the port or combination[...]
Rodent Swivel-Tether Connector
High-impact thermoplastic or stainless steel swivels, with precision stainless steel hypodermic tubing, and PTFE seals. Offering single fluid channels in a range of tubing gauges. Use the Order Form to complete a purchase, or contact us with questions. SIV swivels include tether block BS and RS swivels - RS T1[...]
Supplies for Hyperinsulinemic-Euglycemic Clamp Studies
This protocol uses an IV infusion of insulin to set a baseline, as well as variable rate infusion of glucose (into the same IV line). It’s also common to incorporate an additional channel for IV dosing of an experimental compound. Intermittent blood sampling determines the impact of the drug administration on the rat.
Rounded tipped rodent jugular vein catheter with beads at 2.6 and 3cm from the tip
You will find a wide variety of JVC options below, but all of these catheters are constructed of biocompatible materials for low vessel trauma and increased patency. Rounded Tip- Our most popular catheters are our rounded-tip catheters. Rounded tips reduce trauma during implant as well as during subsequent catheter manipulation leading to[...]
Rat Femoral Polyurethane Artery Catheter
Rat arterial catheters are designed to enter the smaller, more muscular vessels while maintaining strength and durability at the externalization point. SAI offers both a tapered and a step-up option. Minimum order quantity is 5 pieces. For pricing on fewer than 5 catheters, please contact us. For placement in rat arteries, including carotid[...]
Bile collection 25G swivel to tube extension lines 3/pk
This extension line is a perfect fit for our CannuLock™ Bile Collection System. The polyurethane tubing is press fit to the 25G dual pin swivel and runs from the top of the swivel down to your collection vial. 3/pk, ETO sterilized Fits 25G Swivel Connection 33″ length, or request the[...]
CannuLock™ Ports, 25G Red, 10 sterile pouches of 2 each, 20 ports total
SAI's Catheter Access Ports™ offer all new CannuLock™ technology, providing a remarkably secure connection between your catheter and the port. The carefully designed barbed connector locks with the catheter to eliminate the risk of slipping or disconnecting. CannuLock™ technology is also available in our Catheter Access Button™. Smooth barb safely "locks"[...]
Shunting Cap, Multi-Channel CAB, P1 and P3
These lightweight metal caps connect and protect SAI Catheter Access Buttons™, allowing you to group house your animals without worry. Catheter Access Button™ Standard Caps Magnetic, so cap is self-aligning, attaching quickly and easily Cap is lightweight but durable, allowing worry free group housing Three colors available for easy identification of[...]
Triple Channel CAB w/ CannuLock™ , 22G
Our safe and secure rat Catheter Access Buttons™ feature CannuLock™ technology for the best catheter fit. The smooth barbed connector locks with a catheter to eliminate the risk of slipping or disconnecting. You may also like CannuLock™ ports, adapters and tethers. Smooth barb safely "locks" with a catheter to eliminate disconnections[...]
12” Quick Connect Tether, Single Channel CAB, 22G P2
SAI's Catheter Access Buttons™ offer all new CannuLock™ technology, providing a remarkably secure connection for up to three catheters. Our 1, 2, and 3 channel tethers make connections even easier with smart alignment features. The alignment arrows and unique “keyed” geometry of SAI's buttons allow you to access only the port or combination[...]
Rodent Swivel-Tether Connector
High-impact thermoplastic or stainless steel swivels, with precision stainless steel hypodermic tubing, and PTFE seals. Offering single fluid channels in a range of tubing gauges. Use the Order Form to complete a purchase, or contact us with questions. SIV swivels include tether block BS and RS swivels - RS T1[...]